Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Variable Requirements
Temperature Maximum rate of change: 18°F (10°C) per hour
Nonoperating: -55° to 150°F (-48.3° to 65.5°C)
Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters)
Altitude
10,000 feet (3,048 meters) maximum
Humidity
Operating wet bulb: Not to exceed 91.4°F (33 °C) (with diskette drive
or hard drive)
Nonoperating: 95% relative (noncondensing) at 86° F (30° C)
Shock
Operating: 2.0 g, 11 msec, ½ sine
Packaged: Operational after 30-inch free fall (cosmetic damage might
occur)
AC input power 100-240 V, 8.0 A, 50/60 Hz